Posted on

Repair Guide for Sonicare EasyClean Toothbrush Published – Philips HX6530

We’ve been quietly working away here at Ionic Industries and have just published our latest toothbrush battery replacement guide. This time we have been repairing a Philips Sonicare electric toothbrush, the EasyClean HX6530, which takes a Lithium-ion (Li-ion) 3.7V rechargeable battery.
The EasyClean models are expensive toothbrushes so we hope you can repair yours rather than having to throw it away and buy a whole new one. Take a look at the full Sonicare EasyClean battery replacement guide here or leave your comments, questions and tips below!

Philips-Sonicare-HX6530-Battery-Replacement

34 thoughts on “Repair Guide for Sonicare EasyClean Toothbrush Published – Philips HX6530

  1. Hi, I have replaced the battery that I brought earlier and it powered on, however, I have problem recharging it. I see my JP1 connection are joined properly. Any suggestion?

    1. Hi, I’d suggest checking the solder connections for the battery and that the wire pins haven’t been pulled off the ends of the battery. Also check that the copper wires from the charging coil at the bottom of the handle are connected to their PCB pins still, and verify that charger is working correctly. Does the charging indicator light up when the brush is put on to charge?

  2. Tried all. And the charging indicator light is not up. Which are the jumpers that matters for the recharging? I will see if I should re-solder those jumpers again.

    1. Only JP1 and the two connections to the battery (+ and -)
      Try re-soldering those and you should get some indication of charging, especially if the brush runs when it’s not on charge.

  3. Battery is good, how do I trouble shoot the motor. The unit does num , but does not Vibratie

    1. Once you’ve got the toothbrush open tighten the screw that couples the metal output shaft to the motor.

  4. Can I replace HX6932’s battery to HX6710’s?

  5. SANYO 4235 010 18531 can be replaced with SONY 4235 010 15212 ?

    1. Yes, as long as they are both Li-Ion type batteries then they can be interchanged. They can both be replaced with our Li-Ion replacement battery for Sonicare available in our online shop.

  6. Hi folks.

    First of all. Thank you very much for your website and the guides. My Sonicare Diamondclean (HX9340) broke a few weeks ago. With your guide I was able to open the Sonicare. Unfortunately, it was not the battery. Thus, I had to buy a new one. I decided to buy the Sonicare Easyclean (HX6530) instead of the Diamondclean. I am happy with that decision, because the Easyclean works very well.
    But I asked myself it would be possible to move the mechanic life of the Easyclean to the handpiece of the Diamondclean, because I still have the accessories like the travel case (the handpiece of the Easyclean doesn’t fit completely into the travel case of the Diamondclean). On the pictures the mechanic life inside of the handpiece of the Easyclean (HX6530) looks very similar to the Diamondclean (HX9340). Does someone of you tested that or know if that would be possible? Thank you very much for your comments and best regards.

    1. Hi Ramon, It’s good to hear that the guide was useful in opening your DiamondClean. Regarding fitting the internals of the EasyClean into the DiamondClean casing, I think the main issue will be the different PCBs which might be different sizes and have different locations for the switch. If the switch is in the same place then it might be possible. Also note that the DiamondClean has a ferrite bead inside the charging coil which will need to remain with the DiamondClean handle for charging. Let us know how you get on!

  7. Hey Ionic Admin :).

    Thanks. Sure, I will let you know. I didn’t know that I have to change the charging components as well. Let’s see.

  8. Hi,

    Many thanks for the guide. I have a Sonicare toothbrush which was no longer accepting a charge (lights not showing) so I disassembled it, there was some moisture and slight rusting on the battery (along with a bit of gunk elsewhere).

    How do I know if it’s the battery that was the problem, or if something else has broken? I used a multimeter and the battery seems to give off 2V, not the 3.7V that should be expected. Will the battery be the problem, or could it be something else?

    Thanks!

    1. Hi Blair, firstly let the dismantled handle dry out for a day or two in a warm room or cupboard. Then try charging it again. If the battery still won’t charge and measures 2V then this is too low and below the spec for a healthy Li-ion battery even when discharged, so it will need replacing.

  9. Thank you for posting this guide! I wish i’d had it prior to troubleshooting my Sonicare. Unfortunately, in my haste, the bottom pieces (plastic battery cover) of two toothbrushes were slightly damaged. They both still charge, but rest on the charger a little lopsided! Lol! I can’t seem to find replacement pieces anywhere. Do you all sell those or know where i can find them?
    Thank you so much!

    1. Hi Cynthia, you might be able to find spare caps for the base of the handle on eBay. Alternatively you could buy a whole faulty toothbrush and take the cap off that!

  10. Hi,

    Many thanks for the quick reply and battery.
    Prior to soldering it into the handle I’m trying to work out if the battery is the problem, as once I solder it in I obviously can’t return it.

    Do you know if the charging LED should appear when I hold the new battery on the connectors ? (as shown in this image: http://i.imgur.com/aFVttNW.jpg )
    It effectively looks the same as if it was soldered in properly, yet nothing appears when it’s put on the charging stand (nor does it turn on).

    Thanks!

    1. Hi Blair, holding the battery in place like that is not recommended because if you momentarily disconnect the battery while it’s charging you could blow the charging circuitry. It will also only work if JP1 is reconnected. You could solder some test pins (pieces of metal paperclip) to the PCB and then use test leads with crocodile clips at each end to connect the battery if you want to test without soldering to the battery pins.

  11. Hi..many thank for the pics ! Worked so far and runs again !
    **One additional detail : **
    Using the grips and pressing onto the table, didn’t work for me.
    It didn’t pop out..and I used all my strength 🙂
    So I had to use a thin srewdriver and lever the cap (pry open) out.
    Now I have some marks on the plastic-edge..but no problem for me.
    And it didn’t pop out, because there are 2 black plastic clips inside who kept
    the inner system in position.
    I had to use the screwdriver again to move them a bit and let it loose, then everything came out

  12. Hi I replaced the battery on my HX6530 in the hope that it was the problem, but it’s still the same… The toothbrush actually works OK, but when it’s on the charging base, it makes a repetitive beep, beep-beep, beep, beep-beep sound, and the charging indicator flashes orange/green/orange in time with the beeps. The unit does apppear to charge, but obviously the beeping and flashing indicates a fault of some sort. I did clean off all of the electrical parts, pcb etc with alcohol and a nailbrush, and gave ’em a squirt of WD40. I don’t know what else to try!

    1. Strange! I’m not sure what that beeping means. On some Sonicare toothbrushes 3 beeps indicates low charge. There might be an issue with the charging circuitry but you could try running the toothbrush until the new battery is flat then give it a full charge.

  13. Hello my HX6950 stopped fully charging only two of the three charge lights lit, then one. The unit was being returned to the charge base after use. Then one yellow light flashing and then flat.
    I changed the battery with a new one. I pushed the button to check it was working and everything fine, two green charge lights showing. I put it on the base for its 24 hour charge. Lights all flashing fine for charging at 18 hours I took it of the base to see how it was going and to my surprise I only had one green light showing, the charge had gone down after 18 hours. At 30 hours I now have one yellow light flashing it is nearly discharged, the unit has been retutned to the charging base every time. Can you advise please.
    Thank you for your help.
    Regards Peter

    1. That’s a strange one! Your FlexCare is very similar internally to the EasyClean. Is there any water damage (staining) to the PCB on either side? Check your solder joints and JP1. Check there are no stray blobs or whiskers of solder causing a short circuit on the PCB. Although the charging lights are low, how long will the brush run for?

  14. I have some different type of battery in my HX6530. It’s SANYO POHC P/N 4235 010 19621, Li-Ion 10. I have used a multimeter and it gives me 5,3 V. Where can I get replacement battery in my case?

    1. Your old battery is reading over-voltage which is probably why it is faulty. They should all read between about 3.0V and 4.2V. Replacement Li-ion Sonicare batteries are available here: http://tinyurl.com/sonibatt

  15. Following your excellent repair guide, I found that the seal between the case and the metal shaft on which the brush is mounted is worn out and leaking and causing corrosion and contamination of the interior of the body. Phillips does not have the seal for sale, so the unit is trash. It appears to me that the seal ought to be replaced periodically as normal flexing with use will eventually wear it out. Any suggestions? Thanks

    1. It’s true that the seal can split. You can dry the unit out by removing the internals for 24 hours and reassembling. Then you can probably continue to use it as normal, provided that after every use you remove the brush head and then store the handle on its side to stop water seeping past the seal.

  16. Hello
    My HX6790 stopped working and I used some online instructions to open it up an take a look. There was moisture on the inside and a little rust on the battery and connectors. I have since switched the battery for a new one and cleaned the rust.
    Now the light comes on when I put it on the charger but it doesn’t seem to want to turn on when I press the button. I think the new battery is in the right way as although I couldn’t see any +ve or -ve indications on it, there is a indent about 3mm down from one end (which was the +ve terminal on the old battery) and I put the new one the same way round. Could it be the wrong way round? Would the charging light come on if it was? Have you got any idea what else I could try if not?

    Thanks

    1. The groove around the battery is at the positive end (on li-ion cells) so it sounds like you’ve installed it correctly. It sounds like there is water damage to the PCB on one side or the other. Look for staining on the tracks and you might find that you can bypass any damage by soldering a fine wire in place.

      1. Ive had a look at the circuit board and there appears to be some of the blue surface of the PCB flaking off a bit on the underside near the charging coil. Apart from that there is a very small area of what looks like water damage on the front. I have a picture which shows it. How can I post it? Was wondering where to put the bypass

        1. Yes those two patches sound like damage. You can upload your photos to an image hosting site then paste the links into your reply here. However, remove the letters “http” from the start of each link so your comment won’t automatically get deleted.

  17. Thank you for your clean disassembly instructions for the Philips Sonicare HX6530.

    The problem was not with the power but with the metal part that the brush fits onto. It was becoming looser and looser although the securing screw seemed tight. Nonetheless, the screw was loosened, the metal part was removed and examined; minimal wear was found, the metal part returned and secured by tightening the holding screw extra tight and the working assembly reinserted into the outer shell. The metal part still wobbles a bit more than when new but is better than it was. The design is deficient and mickey mouse.

    Thank you again. You saved me time and most likely some grief. 🙂

  18. Thank you for your guide! I managed to replace the battery but unfortunately my Flexcare only beeps once long twice short when I try to charge it and it doesn’t seem to charge. However, I can turn the toothbrush on (the new battery was partly pre-charged), but it won’t turn off again until the 2 minutes program has finished. The buttons for the different programs and the level of intensity sometimes work, sometimes not.
    I had to recharge the old battery every four days before I replaced it and in the last weeks the toothbrush sometimes turned itself on and off. I believe that it finally turned itself on and didn’t stop until the (old) battery was completely empty. After that the beeping started, with the old and also with the new battery. But, since the replacement of the battery, it doesn’t turn itself on anymore (yay!). It was a little bit wet and also partly corroded inside, but not very much. Maybe that was the reason why it turned itself on and off, some kind of a short circuit or so.
    Do you probably know how I can fix the issues mentioned above?
    Thank you again!

    1. Hi John, Glad to hear the guide was useful. It sounds like water ingress is the issue and this might have damaged the PCB and switches causing the issues you mention. See our Sonicare Spare Parts page for new seals and our Sonicare PCB Corrosion Repair page. Then once you’ve repaired it read our Toothbrush Care Tips to stop it happening again.

Leave a Reply
Any comments containing links are automatically deleted. Your email address will not be published.